Heat Pump Size Calculator: What Size Heat Pump Do I Need?

Enter your home and state to size a heat pump in tons, see the outdoor temperature where it stops keeping up, and find how many kW of backup heat to plan for.

Units

Sets design temperatures from NOAA climate normals for a major city.

sq ft
ft

Most homes are 10–20%.

Heat pump size3 tons
Cooling load33,100 BTU/h
Heating load36,900 BTU/h
Balance point29 °F

Plan on about 5 kW of backup heat. At 14 °F, the heating design temperature for the median U.S. reference city, a standard heat pump this size puts out about 20,200 BTU/h against a heat loss of 36,900 BTU/h. Above the balance point of 29 °F it heats the house alone; below it, backup heat makes up the difference.

Compare with a gas furnace →

Safety: Heat pump installation involves refrigerant, high-voltage wiring and, for backup heat strips, large electrical loads that need the right breaker and wire. Have a licensed HVAC contractor size and install the system.

A heat pump moves heat instead of making it, so it can heat and cool with the same equipment. Sizing one means balancing two loads. It has to be big enough to cool the house in summer without short-cycling, and it has to heat the house on cold days, when its output falls. This calculator works out both loads for your house and state, picks a size, and shows where the heat pump stops keeping up and how much backup heat fills the gap.

How it works

The cooling and heating loads use the same model as our AC size calculator. Heating adds slab-edge losses and higher winter air leakage, and it takes no credit for sun, people or appliances. The heat pump side works like this:

size          smallest unit covering 95% of the cooling load
            (or of the heating load at the design temperature, if you choose)
output(T)     rated × (1 − slope × (47 °F − T))
            standard:      100% at 47 °F, 60% at 17 °F
            cold-climate:  100% at 47 °F, 75% at 5 °F
heat loss(T)  UA × (70 °F − T)
balance point the T where output(T) = heat loss(T)
backup (kW)   (heat loss − output) at the design temperature ÷ 3,412

Capacity in the cold. Heat pump output is rated at 47 °F and drops as it gets colder outside. We use straight-line curves: a standard heat pump keeps 60% of its rated output at 17 °F, and a cold-climate model keeps 75% at 5 °F, above NEEP’s 70% minimum. Real units vary, and the manufacturer’s extended performance data is the place to check a specific model.

Heating design temperature. It’s the lowest hourly 10th-percentile temperature from December through February in NOAA’s 1991–2020 normals, at the station nearest a major city in your state.

Sizing for heating picks the smallest size whose output at the design temperature covers the heat loss. In cold places that can mean a much bigger unit than the cooling load needs. That works with variable-speed equipment, but a single-speed unit that large will short-cycle in summer.

Worked example

A two-story, 1,800 sq ft house in Minneapolis has good insulation, low-E windows and ducts in the attic. NOAA normals at MSP give a heating design temperature of −9 °F.

  • Cooling load: about 18,200 BTU/h, so a 1.5-ton heat pump covers it
  • Heat loss: about 35,300 BTU/h at −9 °F (446 BTU/h per °F of indoor–outdoor difference)
  • Standard heat pump: at −9 °F it puts out about 4,600 BTU/h. The balance point is about 36 °F, and you’d need about 9 kW of backup heat
  • Cold-climate heat pump, same size: 12,000 BTU/h at −9 °F, a balance point near 33 °F and about 7 kW of backup
  • Sized for heating, a cold-climate unit has to be 5 tons to cover −9 °F on its own. Most owners in this climate choose a 2 to 3-ton cold-climate model and keep 5 to 7 kW of backup

Heat pump balance point by state: reference table

The same 2,000 sq ft home in every state, with a standard heat pump sized for cooling and the backup heat each type needs at the heating design temperature.

Computed by Home Yardstick for a one-story, 2,000 sq ft home with average insulation, double-pane windows and ducts in the attic. Design temperatures from NOAA 1991–2020 hourly normals at the station listed.
State (station)Heating designSizeBalance point, standardBackup, standardBackup, cold-climate
Alabama (Birmingham AP, AL)20 °F3 t29 °F3 kW1 kW
Alaska (Anchorage Merrill Fld, AK)-8 °F2 t38 °F14 kW11 kW
Arizona (Phoenix Sky Harbor Intl AP, AZ)38 °F3.5 t25 °F0 kW0 kW
Arkansas (Little Rock AP Adams Fld, AR)21 °F3 t29 °F3 kW1 kW
California (Los Angeles Intl AP, CA)44 °F2.5 t33 °F0 kW0 kW
Colorado (Aurora Buckley Fld ANGB, CO)9 °F2.5 t33 °F8 kW6 kW
Connecticut (Hartford Bradley Intl AP, CT)4 °F3 t29 °F9 kW5 kW
Delaware (Philadelphia Intl AP, PA)14 °F3 t29 °F5 kW3 kW
District of Columbia (Washington Reagan AP, VA)18 °F3 t29 °F4 kW2 kW
Florida (Jacksonville NAS, FL)34 °F3 t29 °F0 kW0 kW
Georgia (Atlanta Fulton Co AP, GA)21 °F3 t29 °F3 kW1 kW
Hawaii (Honolulu Intl AP, HI)63 °F3 t29 °F0 kW0 kW
Idaho (Boise Air Terminal, ID)14 °F3 t29 °F5 kW3 kW
Illinois (Chicago Midway AP, IL)4 °F3 t29 °F9 kW5 kW
Indiana (Indianapolis, IN)5 °F3 t29 °F8 kW5 kW
Iowa (Des Moines Intl AP, IA)-2 °F3 t29 °F11 kW7 kW
Kansas (Wichita, KS)11 °F3.5 t25 °F6 kW2 kW
Kentucky (Louisville Intl AP, KY)13 °F3 t29 °F6 kW3 kW
Louisiana (New Orleans Lakefront AP, LA)36 °F3 t29 °F0 kW0 kW
Maine (Portland Intl Jetport, ME)0 °F2.5 t33 °F11 kW8 kW
Maryland (Baltimore Wash Intl AP, MD)14 °F3 t29 °F5 kW3 kW
Massachusetts (Boston Logan Intl AP, MA)8 °F2.5 t33 °F8 kW6 kW
Michigan (Detroit City AP, MI)8 °F2.5 t33 °F8 kW6 kW
Minnesota (Minneapolis/St Paul AP, MN)-9 °F2.5 t33 °F14 kW10 kW
Mississippi (Jackson Intl AP, MS)24 °F3 t29 °F2 kW0 kW
Missouri (Kansas City Downtown AP, MO)9 °F3 t29 °F7 kW4 kW
Montana (Billings Logan Intl AP, MT)-1 °F3 t29 °F10 kW7 kW
Nebraska (Omaha Eppley Airfield, NE)0 °F3 t29 °F10 kW6 kW
Nevada (Las Vegas Mccarran AP, NV)32 °F3.5 t25 °F0 kW0 kW
New Hampshire (Manchester AP, NH)1 °F2.5 t33 °F10 kW7 kW
New Jersey (Newark Intl AP, NJ)13 °F3 t29 °F6 kW3 kW
New Mexico (Albuquerque Intl AP, NM)19 °F3 t29 °F4 kW2 kW
New York (New York Laguardia AP, NY)15 °F3 t29 °F5 kW3 kW
North Carolina (Charlotte Douglas AP, NC)21 °F3 t29 °F3 kW1 kW
North Dakota (Fargo Hector Intl AP, ND)-16 °F2.5 t33 °F16 kW12 kW
Ohio (Columbus Port Columbus Intl AP, OH)7 °F3 t29 °F8 kW5 kW
Oklahoma (Oklahoma City Will Rogers AP, OK)18 °F3.5 t25 °F3 kW0 kW
Oregon (Portland Intl AP, OR)29 °F2.5 t33 °F2 kW1 kW
Pennsylvania (Philadelphia Intl AP, PA)14 °F3 t29 °F5 kW3 kW
Rhode Island (Providence T F Green AP, RI)8 °F2.5 t33 °F8 kW6 kW
South Carolina (Charleston Intl AP, SC)27 °F3 t29 °F1 kW0 kW
South Dakota (Sioux Falls, SD)-8 °F3 t29 °F13 kW8 kW
Tennessee (Nashville Intl AP, TN)16 °F3 t29 °F5 kW2 kW
Texas (Houston Intercont AP, TX)32 °F3.5 t25 °F0 kW0 kW
Utah (Salt Lake City Intl AP, UT)14 °F3 t29 °F5 kW3 kW
Vermont (Burlington Intl AP, VT)-7 °F2.5 t33 °F13 kW9 kW
Virginia (Oceana NAS, VA)23 °F3 t29 °F2 kW1 kW
Washington (Seattle Boeing Fld, WA)28 °F2.5 t33 °F2 kW1 kW
West Virginia (Charleston Yeager AP, WV)11 °F3 t29 °F6 kW4 kW
Wisconsin (Milwaukee Mitchell AP, WI)1 °F2.5 t33 °F10 kW7 kW
Wyoming (Cheyenne, WY)7 °F2.5 t33 °F9 kW6 kW

Tips and common mistakes

Choose a cold-climate model where winters are cold. In zones 5 to 7, the difference between a standard and a cold-climate heat pump is often several kW of strip heat on the coldest nights, and strip heat costs about three times as much to run.

Look at the 5 °F and 17 °F capacities. Rated tons only tell you about mild weather. Ask for the model’s output at your design temperature.

Size the backup heat and the electrical service together. A 10 kW strip heater draws about 42 amps at 240 volts. Make sure your panel can carry it.

Keep a dual-fuel option in mind. Pairing a heat pump with a gas furnace lets the furnace take over below the balance point, which can make sense where gas is cheap.

Fix the envelope first. Every BTU of heat loss you remove lowers the balance point. In cold climates, air sealing and insulation often matter more than equipment.

Frequently asked questions

How do I size a heat pump?

Start with the cooling load, because a heat pump is an air conditioner that can run in reverse. Then check the heating side. At your coldest design temperature, a heat pump puts out much less than its rated capacity, so you need backup heat, a cold-climate model or a larger unit to cover the gap.

What is a heat pump balance point?

It's the outdoor temperature where the heat pump's output exactly matches the house's heat loss. Above it, the heat pump heats the house on its own. Below it, backup heat makes up the difference. Lower balance points mean less backup heat and lower bills.

Do heat pumps work in cold climates?

Yes, if you choose a cold-climate model. Under NEEP's specification, cold-climate heat pumps have to deliver at least 70 percent of their rated capacity at 5 °F, and many keep running well below 0 °F. Standard heat pumps lose capacity much faster in the cold.

How much backup heat does a heat pump need?

Enough to cover the difference between the heat loss and the heat pump's output at your heating design temperature. In mild climates that can be zero. In northern states, a standard heat pump sized for cooling can need 5 to 10 kW or more of electric strip heat. A cold-climate model needs less.

Should I size my heat pump for heating or cooling?

In cooling-dominated climates, size for cooling. In cold climates, a slightly larger variable-speed cold-climate unit can cover most of the heating load while still running at low speed in summer to control humidity. A single-speed unit sized for heating will be oversized for cooling.

Sources

  1. Air-Source Heat Pumps, ENERGY STAR (U.S. EPA)
  2. Cold Climate Air Source Heat Pump Specification, Northeast Energy Efficiency Partnerships (NEEP)
  3. U.S. Climate Normals 1991–2020 (hourly), NOAA National Centers for Environmental Information